Call UsCall Us : 07971549348
Electrical Insulating Mat
Electrical Insulating Mat
Electrical Insulating Mat
Electrical Insulating Mat
Electrical Insulating Mat
Electrical Insulating Mat

Electrical Insulating Mat

Price 500.0 INR/ Unit

Electrical Insulating Mat Specification

  • Length
  • 10 meters (standard)
  • Components
  • Mat only
  • Product Type
  • Electrical Insulating Mat
  • Rubber Type
  • EPDM, Nitrile, or Natural Rubber
  • Flame Resistance Level
  • Class 2 (self-extinguishing as per IS 15652)
  • Temperature Resistance
  • -25C to +80C
  • Material
  • Elastomer (natural rubber or blends as per IS standards)
  • Water Absorption
  • < 1% (by weight)
  • Thermal Conductivity
  • Low
  • Size
  • Standard roll length 10 meters, custom sizes upon request
  • Natural Rubber
  • Available in both natural and synthetic rubber compounds
  • Density
  • 1.5 Gram per cubic centimeter(g/cm3)
  • Style
  • Plain or Checkered
  • Tolerance
  • 5% in thickness
  • Surface Finish
  • Textured/anti-skid finish
  • Usage & Applications
  • Electrical safety flooring, control rooms, substations, transformer rooms, generator rooms, near switchboards and high voltage areas
  • Color
  • Black, Blue, Green, or as specified
  • Hardness
  • 65 5 Shore A
  • Feature
  • High dielectric strength, anti-skid surface, moisture and oil resistant, fire retardant
  • Part Type
  • Sheet/Roll
  • Weight
  • Approx. 3.9 kg/m2 for 2.0mm, varies by thickness
  • Width
  • 1 meter or 1.2 meters (custom sizes available)
  • Resistance level
  • Up to 65 kV (as per type/class)
  • Thickness
  • 2mm, 2.5mm, 3mm, as per IS 15652-2006/IEC 61111
  • Tensile Strength
  • 15 MPa (min)
 

Electrical Insulating Mat Trade Information

  • Minimum Order Quantity
  • 10 Meter
  • Payment Terms
  • [, ]
  • Supply Ability
  • 1000 Per Week
  • Delivery Time
  • 1-5 Days
  • Sample Available
  • No
  • Sample Policy
  • m, a, n, o, a, l, e, ', o, u, n, a, u, s, i, o, n, e, g, a, i, g, o, l, i, f, o, i, n, f, o, s, m, p, p, '
  • Main Export Market(s)
  • [, ]
  • Main Domestic Market
  • [, ]
  • Certifications
  • Yes
 

About Electrical Insulating Mat



Utilise this grandiose Special Offer and grab your sensational Electrical Insulating Mat today! Boasting superb electrical resistance at over 1 Megaohm (500V), with dielectric strengths up to 36 kV, this mat truly excels in safety. Designed for loose-laid installation, it features anti-skid, fire-retardant, and oil-resistant properties, ensuring exceptional performance in high voltage areas. Easy to maintain and packaged in sturdy rolls, this mat fits control rooms, substations, switchboards, and generator installations. Available in multiple sizes and colours, with premium natural or synthetic rubber blendsgrab yours from Indias leading manufacturer, supplier, and trader!

Features & Applications of Electrical Insulating Mat

The Electrical Insulating Mat offers sensational safety with high dielectric strength, anti-slip surface, and resistance to fire, oil, and UV. Its phenomenal tear and tensile strength enables superb performance in electrical safety flooring. Commonly utilised in substations, control rooms, and generator or transformer rooms, it safeguards against electrical shocks near switchboards in high voltage environments. Designed for versatile use, it can be installed in varied electrical facilities, ensuring operational security and reliability.


Packaging, Market Scope, & Sample Policy Highlights

The Electrical Insulating Mat is thoughtfully supplied in rolls, carefully wrapped in polyethylene or HDPE to minimise expenditure on damage during transit. Our proposal amount varies according to type, thickness, and dimensions demanded by clients across Indias main domestic market. Sample policy accommodates review, ensuring customers can assess the mats quality prior to bulk purchase. We strive to streamline supply while reducing investment overhead for buyers.


FAQs of Electrical Insulating Mat:


Q: How do you install the Electrical Insulating Mat?

A: The mat is designed for effortless loose-laid installation, requiring no adhesives. Simply unroll the mat in your desired location, such as control rooms or substations, ensuring the area is clean and dry for optimal surface contact and safety.

Q: What are the key benefits of using this mat in electrical environments?

A: This mat provides exceptional dielectric and mechanical protection against electrical shocks, boasts sensational slip, fire, oil, ozone, and UV resistance, and withstands harsh thermal and physical conditionsmaking it invaluable for electrical safety flooring.

Q: Where can I use the Electrical Insulating Mat?

A: You can utilise this mat in control rooms, substations, transformer and generator rooms, and near high-voltage switchboardsany environment that demands superior electrical insulation and safety.

Q: When should I consider replacing the Electrical Insulating Mat?

A: Inspect the mat regularly for any visible damage, surface wear, or loss of mechanical properties; replacement is advised whenever its integrity or anti-skid texture is compromised to maintain peak electrical safety.

Q: What options are available for sizes and finishes?

A: Standard sizes are 1 or 1.2 meters in width with a standard length of 10 meters; custom sizes are available upon request. The mats feature either plain or checkered finishes and are offered in black, blue, green, or colours per client specification.

Q: How can I request samples or obtain a proposal amount?

A: You may request complimentary samples subject to our policy, and proposal amounts are tailored based on your supply requirements, mat thickness, material, and packaging preferencescontact us for a bespoke quotation.

Tell us about your requirement